DAS 4940 - Slimline cooker hood
   

DAS 4940
Slimline cooker hood for installation in narrow wall units with EasySwitch controls  

Price: HK$ 26,000.00 
Article color:  
  • Transp. glass
DAS4940

More product information

Slimline cooker hood for installation in narrow wall units with EasySwitch controls  


  • Perfect combination with Con@ctivity-enabled hobs 
  • Light design – transparent glass panel, 90 cm wide 
  • LED strip for uniform lighting
  • Efficient filtration- 10-ply stainless-steel grease filter

    Stainless steel grease filters (10-layer)

    Looks great and does a good job: effective grease filtering and easy cleaning in a dishwasher.
  • Recirculation mode – Active AirClean or Longlife AirClean filter 

    AirClean or Longlife AirClean filter

    Please note that a DKFS 31-P/-R special initial commissioning set is required for the following models: DAS 2x20, DAS 4x20, DAS 4x30.The DAS 4x40 and 8x30 can be used directly with the DKF 31-P/-R.

Product details - DAS 4940

Construction type 
Slimline cooker hood
Operating modes 
Type of air guide
Can be retrofitted
Recirculation conversion kit (order separately)
DUU 151
Active charcoal filter (order separately)
DKF 31-P
DKF 31-R
Design 
Colour
Transp. glass
User convenience 
Miele@home
Automatic function Con@ctivity
Electronic controls
Touch-on-glass controls
Controls
EasySwitch
Booster levels
1
Programmable Booster level switch-off
Run-on time 5/15 min.

Run-on function

Odour-free room air: after cooking, the fan can be set to switch off automatically after a 5 or 15 minute run-on period.
Grease filter saturation indicator
Grease filter saturation indicator
Active charcoal filter saturation indicator
Cleaning and care 
Easy-to-clean canopy interior – CleanCover
Filter system 
Number of dishwasher-safe stainless steel grease filters (10-ply)
2
Lighting 
LED
Number x W
1 x 3 W
Light intensity in Lx
285 lx
Colour temperature in K
3500 Kelvin
Dimmer function
Fan 
Fan power (m³/h)
1145
Dual-action blower
AC motor
Exhaust air 
Air throughput in Level 1 (m³/h) according to EN 61591
340
Air throughput in Level 2 (m³/h) according to EN 61591
490
Air throughput in Level 3 (m³/h) according to EN 61591
645
Air throughput in booster level 1 (m³/h)
910
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3
51
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
60
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3
67
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3
74
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
37
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
46
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
53
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13
60
Recirculation 
Air throughput in Level 1 (m³/h) according to EN 61591
325
Air throughput in Level 2 (m³/h) according to EN 61591
475
Air throughput in Level 3 (m³/h) according to EN 61591
645
Air throughput in Booster level 1 (m³/h) according to EN 61591
860
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3
58
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
70
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3
74
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3
81
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
44
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
56
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
60
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13
67
Safety 
Safety shut-off
Single-ply safety glass (ESG)
Technical data 
Canopy width in in. (mm)
861
Canopy height in in. (mm)
68
Depth of hood canopy in in. (mm)
307
Net weight in kg
17
Length of supply lead in m
1.8
Standard plug fitted
Total rated load in kW
0.293
Voltage in V
230
Fuse rating in A
10
Frequency in Hz
50
Number of phases
1
Installation notes 
Extraction ducting connection at top
Extraction connection at top and rear
Diameter of extraction ducting connection in mm
150
Fitting template
Accessories included 
Non-return flap

Installation sketch

Whether you want to replace a household appliance or planning a kitchen - under Downloads you can find all relevant installation diagrams for your Miele appliance.

Downloads
Image(s) as examples, to illustrate, product benefits are addicted to the model
EN ZH