KMDA7676FL, KMDA7876FL - Installation variant 6 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
Induction hob with integrated vapour extraction and MattFinish with 2 PowerFlex XL cooking areas for recirculation mode
KMDA7676FL, KMDA7876FL - Installation variant 6 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
KMDA7676FL-U, KMDA7876FL-U - surface installation, drilling template, 23,8 cm, Installation drawing
KMDA7676FL-U BlackPerfection, KMDA7876FL-U - flush installation, drilling template, Installation depth 23,8 cm
KMDA7676FL, KMDA7876FL - Installation variant 4 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
KMDA7676FL, KMDA7876FL - Side view lying on top, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².
KMDA7676FL, KMDA7876FL -Installation variant 3 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90
KMDA7676FL, KMDA7876FL - Side view lying on top - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
KMDA7676FL, KMDA7876FL - flush - Installation drawing
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
KMDA7676FL/FR, KMDA7876FL/FR, Air circulation (Installation drawing)
KMDA7676FL, KMDA7876FL - Installation variant 14 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.
KMDA7676FL, KMDA7876FL - Side view lying on top+X - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
KMDA7676FL, KMDA7876FL - Side view flush+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7676FL, KMDA7876FL - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
KMDA7676FL, KMDA7876FL - Installation variant 13 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.
KMDA7676FL, KMDA7876FL - Installation variant 5 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum depth of the cabinet is 935 mm.
KMDA7676FL, KMDA7876FL - Installation drawing
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
KMDA7676FL, KMDA7876FL - Side view flush, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².
KMDA7676FL-U, KMDA7876FL-U - surface installation, 24,8 cm, drilling template, Installation drawing
KMDA7676FL, KMDA7876FL - Installation variant 1 Basis -drawing
1) DFK-AK 90, 2) DFK-R 1000
KMDA7676FL/FR, KMDA7876FL/FR, Plug&Play (Installation drawing)
KMDA7676FL-U, KMDA7876FL-U - flush installation, drilling template, Installation depth 24,8 cm, Installation drawing
KMDA7676FL, KMDA7876FL - Side view flush - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
KMDA7676FL, KMDA7876FL - Side view lying on top+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is